Upload an ECG, add patient context, and choose automated or manual analysis.
Accepted formats: PDF, JPG, JPEG, PNG
Braunwald, Chapter 9: Electrocardiography — David M. Mirvis and Ary L. Goldberger; supplied PDF, headers dated March 2004. Page numbers refer to PDF pages. Foundational ECG interpretation; current management requires current guidelines.
Check lead placement, signal quality, paper speed and voltage calibration before measuring intervals. At 25 mm/s a small square represents 40 ms. Interpret rate, rhythm, P waves, PR, QRS, axis and ST-T/QT together.
A QRS duration of 120 ms or more warrants assessment for conduction delay. Duration alone cannot identify right or left bundle branch block: lead-specific morphology is needed. Short PR with a delta wave and altered QRS suggests preexcitation.
Bazett correction divides QT by the square root of RR in seconds. QT varies with heart rate and sex; verify the end of the T wave and exclude U waves. Drug and electrolyte effects can alter repolarization. A single corrected value does not establish a long-QT syndrome.
Limb-lead polarity estimates the QRS quadrant. Positive lead I with negative aVF requires lead II to distinguish a leftward normal axis from left axis deviation. Fascicular block requires characteristic morphology and exclusion of alternative causes.
ST elevation, ST depression and T-wave changes require interpretation with distribution, morphology, symptoms and prior tracings. Ischemia may occur without diagnostic ST-T changes. Nonischemic causes include early repolarization, pericarditis, hypertrophy and conduction abnormalities; a checkbox cannot diagnose infarction.
Hyperkalemia can produce peaked T waves, PR prolongation, reduced P waves and QRS widening. Even severe hyperkalemia may lack typical ECG changes. Hypokalemia can produce prominent U waves and altered repolarization. Confirm with laboratory testing.
ECG findings require clinical correlation and comparison with prior records. Computer interpretation needs clinician review. Neither a normal-looking ECG nor isolated measurements exclude important cardiac disease.
AI errors automatically use the knowledge base. Local analysis requires manual measurements and does not read images.